V-Port For Chatter-Free Check Valve Operation

Category: Industrial Refrigeration (Ammonia)
V-Port For Chatter-Free Check Valve Operation


Product Details

Situations:

  • Check valve chattering at low load (fl ow) conditions.


Solutions:

  • Danfoss CHV (check valves) and SCA (stop/check valves) provide an optimum solution to chattering with a V-port design. Active below 25% of opening to maintain adequate velocity at low capacities, the V-port eliminates chatter and noise. Available in angle and globe versions, the CHV and SCA are ideal for discharge lines in reciprocating and screw compressors including economizer